Description
Features
|
Applications
|
Note: THIS IS A SPECIAL ORDER ITEM.
The Altelix NFC201608VFHA1-Z Insulated Heated and Fan Cooled Weatherproof Enclosure with 120VAC Power and Equipment Mounting Plate is ideal for protecting equipment from harsh environments and tampering. Equipment designed for indoor use can now be located outside.
Construction and Features
This rugged enclosure is molded from durable and UV resistant fiberglass reinforced polyester (FRP). The door is fully gasketed making this enclosure suitable for use indoors or outdoors. The lockable door features reinforced hinges and dual quarter-turn latches to secure the enclosure and is locked and unlocked using the included removable keys. A drip rail over the door provides additional protection against water dripping into the cabinet while the enclosure is wet.
Bonus Aluminum Bottle Opener Key
This enclosure now includes our HN-0008 Aluminum Bottle Opener Key. A $9.99 value, this heavy duty aluminum door locking key easily attaches to most key chains. And it makes a great bottle opener too!
Power
This configuration consists of the vented fiberglass NEMA enclosure with hinged lid and a equipment mounting plate with two pre-wired 120VAC power outlets. The outlet box is easily removable to facilitate wiring to an external power source.
200W Heating System
Ideal for cold environments, this model features a thermostat controlled 200W heating system. The heater turns on when the internal temperature reaches 43°F (6°C) and turns off when it rises to 59°F (15°C). The heater is situated below the mounting plate and wired internally so it does not interfere with user installed equipment or require the use of the AC outlets.
Dual Cooling Fans Ventilation
This enclosure features dual 4" vents and dual thermostat controlled cooling fans. The low noise, high airflow fans helps maintain lower internal temperatures by allowing air to be either pushed or pulled through the enclosure. The fans turns on when the internal temperature reaches 100°F (38°C) and turns off when it drops to 79°F (26°C). Both fans are wired internally so it does not require the use of the AC outlets leaving them available for internal equipment use. Rain shrouds on the front door keep rain water from entering the enclosure, and the internal aluminum mesh filters are removable for cleaning.
Insulated Enclosure
Designed for extreme cold and hot environments, the NFC201608VFHA1-Z features 0.500 inch (12.7mm) thick insulation bonded to all interior sides of the enclosure.
Equipment Mounting Plate
The aluminum equipment mounting plate is provided for mounting and securing equipment. The enclosure and plate can be drilled and modified by the installer to suit unique site requirements.
Cable Glands
The enclosure features our unique PG-16 cable glands with a closed inner seal. They are installed in the open ports to maintain the NEMA rating of the enclosure when not in use. When required for use, simply punch a hole through the inner membrane, run your cables and tighten for a water-tight seal. To provide power to the enclosure a 1/2" Liquid-Tight fitting as well as a PG16 Cable Gland are included.
Mounting
Four mounting feet are included so that the enclosure can be securely mounted to a wall or other structure. Optional flange and pole mounting kits are available for this enclosure, see available accessories when adding to cart.
Optional Lockable Latches
For additional protection of internal equipment installed, three lockable latches are available. The HN-0005 is a keyed lock set which includes two keys. Similar to the HN-0005, the HN-0001 has an interlock feature that traps the key when it is in the unlocked position. The HN-0006 allows the enclosure to be securely locked via use of a padlock (not included). All of these optional lockable latches are direct replacements for the standard quarter-turn latches that come pre-installed in the enclosures.
Customization
This enclosure is one of many standard models available. Our lineup includes enclosures specifically tailored for WiFi equipment, DIN Mount Industrial Controls, POTS Telephones, IP Phones, Device Charging Stations, Security & Safety Equipment, Building & Home Automation and More.
We offer numerous standard models and options including equipment mounting plates, DIN rails, AC or DC power, air vents, cooling fans and heaters and more. We also offer full customization, engineering and on-site CNC machining of enclosures and associated equipment, all with quick turnaround time. Please contact us with your unique requirements.
Technical Specifications
Material | Fiberglass Reinforced Polyester |
Color | Light Gray |
Voltage | 120VAC |
Max Load | 15A @ 120VAC |
Heater Turn-On Temperature | 43°F (6°C) ±5°F |
Heater Turn-Off Temperature | 59°F (15°C) ±5°F |
Heater Power | 200 Watt |
Cooling Fans Turn-On Temperature | 100°F (38°C) ±9°F |
Cooling Fans Turn-Off Temperature | 79°F (26°C) ±9°F |
Insulation Thickness | 0.500 Inch (12.7 mm) |
Insulation R-Value | 2 |
Outer Dimensions | 19.7 x 15.8 x 9.4 Inches (500 x 402 x 239 mm) |
Inner Dimensions* | 14.2 x 14.2 x 4.2 Inches (362 x 362 x 108 mm) |
Equipment Plate Dimensions | 13.7 x 17.9 In. (348 x 455 mm) |
Equipment Plate Material | 0.10 in. (2.5mm) Aluminum |
Weight | 18.5 lbs. (8.4 kg) |
Ratings | NEMA Type 3R, 3RX / IP24 |
*Interior dimensions represent space available for equipment. See drawing for additional details. |
NEMA Ratings and IP Equivalency Chart |
Need a pole mount kit or an extra set of enclosure keys? Click the ADD-ONS and ACCESSORIES button below to see all the available accessories for this enclosure.